Skip to content

Industrial Electrical Contractor in Tampa Bay Built for
Continuous Production.

High-amp power distribution, switchgear line-ups, motor control centers, VFDs, and plant automation for manufacturing facilities, logistics hubs, and industrial plants across Central Florida. Industrial facilities cannot afford unscheduled downtime, so we plan around your production schedule, not the other way around.

(813) 778-5992
  • 01 480V 3Φ
  • 02 Switchgear
  • 03 MCC
  • 04 VFDs
  • 05 PLC
  • 06 Shutdowns

Why It Matters

Industrial electrical isn't commercial electrical with bigger wire. The stakes are higher, the equipment is more complex, and a mistake costs your facility real downtime and real money. We've worked inside GE facilities and full plant overhauls. We know how this goes.

Capabilities

Industrial Capabilities

FL Electrical Contractor #EC13014766 · ISN Certified · OSHA 10 / 30 crews

  • 01

    3-Phase Distribution & Switchgear

    480Y/277V and 208Y/120V main switchboards, high-amp service entrance switchboards and CT cabinets, and step-down dry-type transformers.

  • 02

    Busway & Equipment Drops

    Overhead bus duct and busway feeds for flexible equipment drops and rapid machinery reconfiguration.

  • 03

    Power Quality

    Power factor correction and harmonic filtration so variable loads stop tripping sensitive machinery.

  • 04

    Motor Control Centers

    Custom motor starter panels, MCC bucket maintenance, overhaul, and commissioning for pumps, compressors, and packaging lines.

  • 05

    VFDs & Soft Starters

    Variable frequency drives and soft starters, with shielded VFD cable routing to prevent motor bearing currents and noise.

  • 06

    Controls & PLC Integration

    Conveyor control wiring, PLC integration, and emergency-stop and safety interlock loops.

  • 07

    Plant Maintenance & Shutdowns

    Scheduled turnaround and outage support, emergency fault remediation, and night and weekend shutdowns that preserve production.

  • 08

    Testing & Diagnostics

    Arc flash risk assessments, infrared thermal panel scans, and breaker trip testing to find problems before they become outages.

How We Run It

Five Steps.
No Surprises.

  1. STEP 01

    Walk & Review

    Site walk, one-lines, and equipment review with your maintenance and production leads.

  2. STEP 02

    Shutdown Plan

    Outage windows, lockout/tagout points, and sequencing agreed in writing before anyone opens a panel.

  3. STEP 03

    Install

    Licensed crews working under NFPA 70E and LOTO, staged to keep the rest of the plant running.

  4. STEP 04

    Test & Commission

    Insulation resistance, rotation, and functional checks on drives, starters, and interlocks.

  5. STEP 05

    Document & Hand Off

    Updated panel schedules, labeling, and as-builts your maintenance team can rely on.

Codes & Standards

Built to the Book.

NFPA 70 (NEC 2026)
National Electrical Code
NFPA 70E
Electrical safety & arc flash
NFPA 70B
Electrical equipment maintenance
OSHA 29 CFR 1926 / 1910
Construction and general industry safety
ISNetworld
Contractor prequalification (certified)

Proof

Earned in the Field.

  • 01

    General Electric

    Industrial plant electrical maintenance and shutdown support for GE.

  • 02

    Riverhawk Industrial Supply

    Full facility electrical overhaul in Mulberry: all voltage levels, motor controls, and underground conduit banks.

  • 03

    ISN Certified

    Pre-vetted for industrial and high-hazard environments through ISNetworld.

“We run a tight production schedule and can't afford electrical delays. Ohm Grown coordinated the 3-phase service and panel work around our line without ever shutting us down. Clean install, on budget, zero inspection comments.”
Operations Director, Manufacturing Facility · Tampa, FL

FAQ

Straight
Answers.

Can you work without shutting down production?

Yes, in most cases. We plan around your production schedule, stage work in phases, and run night and weekend shutdowns when a line has to come down.

Do you perform arc flash assessments and infrared scans?

Yes. Arc flash risk assessments, infrared thermal panel scans, and breaker trip testing are part of our plant maintenance and shutdown support.

Do you work on MCCs, VFDs, and PLC wiring?

Yes: MCC bucket maintenance and overhaul, VFD and soft-starter installation with shielded cable routing, and conveyor, PLC, and safety interlock wiring.

Are you ISN certified for industrial sites?

Yes. Ohm Grown is a certified contractor on ISNetworld, the platform many industrial operators and Fortune 500 companies use to prequalify contractors.

How does Ohm Grown handle job site safety?

We follow OSHA 29 CFR 1926 and NFPA 70E, keep current OSHA 10 and 30 certifications, and run site-specific safety plans, lockout/tagout procedures, and arc flash protection on every job.

Service Area

  • Tampa
  • Brandon
  • Riverview
  • Plant City
  • St. Petersburg
  • Clearwater
  • Largo
  • Wesley Chapel
  • New Port Richey
  • Zephyrhills
  • Lakeland
  • Winter Haven
  • Auburndale
  • Bradenton
  • Palmetto
  • Sarasota
  • Venice
  • North Port
  • Brooksville
  • Spring Hill

Florida-based, with travel crews for Georgia, Alabama, South Carolina, North Carolina, Tennessee, Virginia, Texas, Arizona, Nevada, and beyond. Service areas & travel →

Next Service

Disaster Recovery

Planning a Shutdown or Upgrade?

Tell us the equipment, the window, and the deadline. We will come back with a plan that keeps your line running.

(813) 778-5992

Connect With Us

We respond within one business day. After-hours emergency: call us directly.